How a Gas Turbine Peak Shaving System Can Reduce Industrial Demand Charges
For industrial facilities, some of the most expensive electricity may be consumed during just a few minutes each month. Utility demand charges are commonly based on a facility’s highest 15-minute average power draw during the billing period. According to the FlexEnergy peak shaving white paper, demand charges can account for 30% to 70% of a commercial or industrial electric bill.
A gas turbine peak shaving system offers another way to address these costs: generate power onsite to continuously reduce the amount of electricity the facility draws from the utility.
How Gas Turbine Peak Shaving Works
Traditional peak shaving focuses on reducing grid demand when electrical loads reach their highest levels. FlexEnergy takes a continuous-generation approach using its Flex Turbine® GT333S microturbine.
Operating in grid-parallel mode, one GT333S generates 333 kW of continuous onsite power. Because that electricity serves facility loads behind the utility meter, the meter sees the facility’s total electrical demand minus the power generated by the turbine.
Demand Curve: Before and After Microturbine Baseload
For example, if a facility reaches a 1,000 kW peak while a 333 kW turbine is operating, its metered demand would be reduced to 667 kW. The white paper illustrates that at a demand charge of $15/kW per month, this reduction equates to approximately $4,995 in monthly demand-charge savings, or about $60,000 annually. Actual savings depend on the site’s utility tariff, operating profile, and electrical load.
More Than Peak Demand Reduction
A continuous gas turbine peak shaving system can potentially address several components of industrial energy cost.
In addition to lowering metered demand, onsite generation can reduce purchases of higher-cost electricity during time-of-use peak periods. It can also reduce exposure to coincident-peak charges under applicable utility tariffs.
Facilities using combined heat and power (CHP) can create another source of savings. The GT333S can provide up to 545 kW of recovered exhaust heat for applications including process heating, hot water, steam, or absorption chilling, potentially displacing boiler fuel.
When Does Industrial Peak Shaving Make Sense?
According to FlexEnergy, continuous microturbine peak shaving is particularly suited to industrial facilities where:
- Demand charges exceed 20% of the monthly electric bill
- Operations run two or more shifts and exceed 5,000 hours annually
- Coincident-peak charges apply
- Time-of-use rates make daytime electricity more expensive
- Production loads cannot easily be shifted to off-peak periods
The Flex Turbine GT333S provides 333 kW of continuous electric output and is designed for grid-parallel or island operation using natural gas, biogas, or associated gas. The white paper reports 99%+ fleet-average availability.
Evaluate the Opportunity at Your Facility
For facilities facing significant demand charges, a gas turbine peak shaving system can turn onsite generation into a predictable reduction in utility demand while potentially adding time-of-use and CHP savings.
Download the full FlexEnergy peak shaving white paper to see the peak-shaving model and determine whether continuous onsite generation fits your facility’s load profile.